42110 HIMA Planar4 Logic Module | New & Original StockHIMA 42110 Planar4 Safety System Logic Function Module The HIMA 42110, also cataloged as the 42110 Logic Function Module, operates as a dedicated hardware component for safety critical logic processing within Planar4 safety system platforms. Hardware Specifications Parameter Specification Model 42110 (Alternate Part No: 984042110) Brand HIMA Origin Germany Weight 0. 31 lbs (0. 14 kg) Dimensions 3U height, 4SU width standard Planar4 rack slot footprint
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

HIMA 42110 Planar4 Safety System Logic Function Module

The HIMA 42110, also cataloged as the 42110 Logic Function Module, operates as a dedicated hardware component for safety-critical logic processing within Planar4 safety system platforms.

Hardware Specifications

Parameter Specification
Model 42110 (Alternate Part No: 984042110)
Brand HIMA
Origin Germany
Weight 0.31 lbs (0.14 kg)
Dimensions 3U height, 4SU width standard Planar4 rack slot footprint
Operating Temp 0 deg C to +60 deg C
Power Consumption 24 W (140 mA current consumption)
Supply Voltage 24 V DC nominal
Logic Functions 8 independent configurable logic functions (AND, OR, NOT, XOR)
Input Channel Count 2 hardware input channels
Reaction Time 2-6 ms
Reset Time 8 ms
Fault Monitoring Internal microcontroller supervision with ERR signal output
Status Indicators RDY (Ready) signaling for supply thresholds >= 20 V DC
Safety Certification SIL 4 compliant (IEC 61508)
Mounting Style Rack-mounted on standard Planar4 backplane

Fail-Safe State Execution and Safety Architecture

The HIMA 42110 executes hardwired solid-state boolean logic combinations to enforce immediate fail-safe state execution upon detection of out-of-bounds parameter boundaries. Engineered to fulfill SIL 4 safety system criteria, the module bypasses standard software operating system dependencies to prevent processor execution freezes. The internal hardware matrix continuously monitors the 2 sensor inputs through integrated microcontroller supervision. If a component fault or an input loop open-circuit occurs, the module forces its internal safety relays to de-energize, opening the diagnostic contact and driving the associated safety loops to a predictable, de-energized shutdown state.

Frequently Asked Questions

Q: How does the 42110 module manage power supply dips without triggering spurious safety trips?

A: The onboard diagnostic block monitors the incoming 24 V DC supply line. The RDY (Ready) status indicator remains active as long as the supply voltage stays at or above 20 V DC. If the voltage drops below this 20 V DC threshold, the internal monitoring routine flags a power fault and commands the logic matrix to initiate its safe state shutdown sequence.

Q: Can this logic module be hot-swapped within the Planar4 rack assembly while active loops are operational?

A: No. Hot-swapping the module while the backplane bus or field loops are energized can generate inductive spikes that risk damaging the solid-state logic gates. The specific Planar4 sub-rack slot must be electrically isolated before extracting or inserting the unit to maintain system stability.

Field Installation Guidelines

  • Sub-Rack Placement and Insertion: Slide the module into the designated 3U height, 4SU width slot of the Planar4 sub-rack. Ensure the rear Eurocard connectors align flush with the backplane receptacles before applying final seating force.
  • Input Signal Shielding: Terminate all dual-channel input sensor cables using continuous braided shielding. Ground the shield at the single entry point of the enclosure terminal assembly to prevent electromagnetic noise from causing logic processing jitter.
  • Enclosure Thermal Control: Maintain vertical clearance profiles within the main enclosure to ensure ambient air temperatures around the rack remain within the 0 to +60 deg C limits. Convective airflow must not be restricted near the 24 W dissipation zones.
  • Fault Output Wiring: Connect the ERR signal output contacts to the centralized master alarm monitoring circuit. Wire this loop using a normally closed configuration so that any internal hardware fault or power loss causes the monitoring contact to open immediately.

42110 HIMA Planar4 Logic Module | New & Original Stock

Item no : 34777256833
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 30 - Jul 5

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches